DUST COLLECTION GLOSSARY

Axial Fan

IN BRIEF
An axial fan moves air mainly parallel to the fan shaft. It is commonly used for high-airflow, relatively low-pressure industrial ventilation and selected dust collection applications.

An axial fan is a type of industrial fan that moves air mainly parallel to the fan shaft.

Its operating principle is similar to a propeller. As the blades rotate, they generate aerodynamic forces that move air through the fan in an axial direction.

Axial fans are commonly associated with:

  • High airflow
  • Relatively low to moderate pressure
  • Compact installation
  • Industrial ventilation
  • Clean-air exhaust
  • Make-up air systems

In industrial dust collection, axial fans are generally less common than centrifugal fans as the main system fan because dust collectors and duct networks often require higher static pressure.

However, axial fans can still be useful in specific ventilation and clean-air applications.

How Does an Axial Fan Work?

In an axial fan, air enters and leaves the fan in approximately the same direction as the rotating shaft.

The blades act like airfoils. As they rotate, they create a pressure difference across the blade surfaces and push air forward.

Unlike a centrifugal fan, an axial fan does not normally redirect the airflow approximately 90 degrees through the impeller.

This straight-through configuration can provide several advantages:

  • Compact dimensions
  • High airflow capacity
  • Relatively low rotating mass
  • Convenient installation in straight duct sections

The exact pressure capability depends heavily on the fan design.

What Are the Main Types of Axial Fans?

Several axial fan designs are commonly used in industrial ventilation.

Propeller Fan

A propeller fan is one of the simplest axial fan designs.

It typically has a small number of relatively broad blades and is commonly used for:

  • Wall exhaust
  • General factory ventilation
  • Air circulation
  • Low-resistance ventilation

Propeller fans generally provide high airflow but relatively low static pressure.

Tubeaxial Fan

A tubeaxial fan places the axial impeller inside a cylindrical housing.

This configuration makes it suitable for installation directly into a duct system.

Typical applications include:

  • Duct ventilation
  • Industrial exhaust
  • General process ventilation

Compared with a basic propeller fan, a tubeaxial fan is better suited to ducted systems with moderate resistance.

Vaneaxial Fan

A vaneaxial fan includes guide vanes before or after the impeller.

These vanes help control rotational airflow and recover part of the air’s velocity energy as useful pressure.

As a result, vaneaxial fans can provide higher pressure capability than many conventional propeller or tubeaxial designs.

This is why it is inaccurate to say that every axial fan is suitable only for very low-pressure applications.

What Are the Main Characteristics of an Axial Fan?

A typical axial fan is selected when a system requires:

High Airflow + Relatively Low or Moderate System Resistance

Compared with many centrifugal fans of similar airflow capacity, axial fans can offer:

  • More compact construction
  • Lower equipment weight
  • Straight-through airflow
  • Convenient duct installation

However, depending on the design and operating point, axial fans may also produce relatively high noise levels.

Their performance can also become unstable if the fan operates too far away from its intended design range.

Axial Fan vs. Centrifugal Fan

The main difference between axial and centrifugal fans is the direction in which air moves through the impeller.

Axial Fan

Air moves mainly parallel to the fan shaft.

Typical characteristics include:

  • High airflow
  • Compact construction
  • Low to moderate pressure capability
  • Common use in ventilation and clean-air applications

Centrifugal Fan

Air enters near the center of the impeller and is accelerated outward in a radial direction.

Centrifugal fans generally provide stronger pressure capability and are widely used for:

  • Dust collection
  • Process exhaust
  • Long duct systems
  • Material handling
  • High-resistance filtration systems
  • Dust-laden air

For this reason, centrifugal fans are usually more common in industrial baghouse and cartridge dust collection systems.

Why Do Dust Collectors Usually Use Centrifugal Fans?

An industrial dust collection system may include resistance from:

  • Collection hoods
  • Branch ducts
  • Main ducts
  • Elbows
  • Cyclone separators
  • Filter bags
  • Filter cartridges
  • Spark arrestors
  • Dampers
  • Silencers
  • Exhaust stacks

All of these components contribute to total system pressure loss.

A central dust collection system may therefore require several thousand pascals of static pressure.

Many conventional axial fans are optimized for high airflow at lower resistance.

Centrifugal fans are generally better suited to overcoming the higher pressure losses associated with:

hoods + ductwork + filtration equipment + exhaust components

This does not mean that an axial fan cannot be used in a dust collection system. It means that the fan type must match the actual airflow and pressure requirements.

Can an Axial Fan Handle Dust-Laden Air?

Some axial fans can handle contaminated air, but not every axial fan is designed for direct dust transport.

Dust-laden air can create problems such as:

  • Blade erosion
  • Dust buildup
  • Impeller imbalance
  • Increased vibration
  • Reduced efficiency
  • Motor contamination
  • Increased bearing stress

Abrasive particles can accelerate blade wear.

In some direct-drive axial fans, the motor is also located directly in the airflow, which may make certain dusty applications unsuitable.

Combustible dust introduces additional concerns, including:

  • Static electricity
  • Mechanical sparks
  • Hot surfaces
  • Motor classification
  • Explosion protection
  • ATEX or other Ex requirements

A standard ventilation axial fan should therefore not automatically be used to transport industrial dust.

Where Are Axial Fans Used in Dust Collection Systems?

Axial fans may be used in several supporting roles around a dust collection system.

General Factory Ventilation

They can exhaust warm, contaminated, or stale air from production areas where high-pressure extraction is not required.

Make-up Air

Large dust collectors can remove significant amounts of air from a building.

If replacement air is not supplied, the building may develop excessive negative pressure.

Axial fans may be used in make-up air systems to introduce outdoor air and help maintain building pressure balance.

Clean-Air Exhaust

Where air has already passed through suitable filtration equipment, an axial fan may be considered on the clean-air side if the required system pressure is within its performance range.

Low-Resistance Fume Exhaust

Certain industrial fumes or low-particle-concentration exhaust applications may also use tubeaxial or vaneaxial fans.

The final selection should always be based on the required fan performance rather than the application name alone.

Is an Axial Fan Always a Low-Pressure Fan?

No.

Pressure capability varies significantly between axial fan designs.

A basic propeller fan usually provides relatively low static pressure.

A tubeaxial fan can handle greater duct resistance.

A vaneaxial fan can provide substantially higher pressure because guide vanes improve airflow control and pressure recovery.

Therefore, the term axial fan alone is not enough to determine whether a fan is suitable.

The correct method is to review its:

Fan Performance Curve

What Is an Axial Fan Performance Curve?

A fan performance curve shows how fan performance changes across different operating conditions.

Important parameters may include:

  • Airflow
  • Static pressure
  • Total pressure
  • Fan power
  • Efficiency

The duct system also has its own resistance curve.

The actual operating point occurs approximately where the:

Fan Curve intersects the System Curve

For example, a fan advertised as providing 30,000 m³/h does not necessarily deliver 30,000 m³/h after it is connected to a real duct system.

As system resistance increases, the actual airflow can decrease.

Industrial fan selection must therefore consider both:

Required Airflow + Required Pressure

rather than airflow alone.

What Is Axial Fan Stall?

Axial fans can experience stall when they operate in an unstable region of their performance curve.

Stall occurs when airflow around the blades begins to separate under unfavorable operating conditions.

Possible symptoms include:

  • Airflow fluctuation
  • Increased noise
  • Vibration
  • Reduced efficiency
  • Increased mechanical stress

This is particularly important in systems where airflow changes significantly during operation.

Fan selection should therefore avoid unstable operating regions.

Can an Axial Fan Use a VFD?

Yes.

A Variable Frequency Drive (VFD) can adjust motor speed and therefore change fan performance.

It can be used to control:

  • Airflow
  • Pressure
  • Power consumption

VFD control can be useful where ventilation demand changes during operation.

However, the reduced-speed operating point must still remain within the stable region of the fan curve.

A VFD cannot correct a fan that is fundamentally unsuitable for the required airflow and system resistance.

How Is an Axial Fan Selected?

Important selection parameters include:

  • Required airflow
  • Required static pressure
  • Total pressure
  • Air temperature
  • Air density
  • Dust concentration
  • Particle characteristics
  • Corrosive components
  • Installation location
  • Indoor or outdoor use
  • Noise requirements
  • Motor power
  • Motor protection
  • Direct or belt drive
  • Fan speed
  • Fan efficiency
  • Required ATEX or Ex classification

The most important principle is:

Fan selection should be based on both airflow and system resistance, not airflow alone.

For systems involving high dust loading, long duct runs, filters, cyclones, or significant pressure loss, a centrifugal fan should also be evaluated.

Is an Axial Fan Suitable for Industrial Dust Collection?

It can be suitable, depending on where and how it is used.

Axial fans are commonly appropriate for:

  • General ventilation
  • Make-up air
  • Clean-air exhaust
  • Low-resistance industrial exhaust
  • Selected process ventilation

For a typical central dust collection arrangement such as:

Hood → Ductwork → Cyclone → Dust Collector → Filter → Exhaust

the system usually requires higher static pressure.

In these applications, a centrifugal fan is generally the more common choice.

Neither fan type is universally better.

The correct choice depends on the required airflow, pressure, air characteristics, dust properties, and operating conditions.

IN THIS ARTICLE
NEED HELP WITH SYSTEM SIZING?

Share your dust source, airflow and operating conditions with our engineering team.

BROWSE THE GLOSSARY

Explore industrial dust collection terms, formulas and system design concepts in alphabetical order.

PROJECT INQUIRY

Tell Us About Your Dust Collection Project

Novazure General Inquiry Form